ILIFE Auto‑Dock / Homing Failure

Robot vacuum does not return to the charging dock automatically

Advertisements

Possible Causes

Dock placed in cramped or obstructed area, IR docking sensor dirty, Strong ambient light interference, Dock power off or adapter faulty

How to Fix / Troubleshooting

Safety first: Keep the robot on the floor while testing docking behavior.

Step-by-step:

  • Reposition dock: Place the dock against a wall with at least 1.5 m (5 ft) clear in front and 0.5 m (1.5 ft) on each side. Avoid corners and under furniture.
  • Verify dock power: Ensure the dock's indicator light is on and the adapter is firmly plugged in.
  • Clean IR windows: Wipe the front IR window on the robot and the dock's IR window with a soft cloth.
  • Reduce interference: Close blinds if strong sunlight hits the dock area. Move mirrors or shiny metal objects away.
  • Test homing: Start the robot a few meters from the dock and press the Home button. Observe its path.

If the robot consistently fails to see the dock even at close range: The IR docking sensor or dock emitter may be faulty and require replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Charging Dock
Check Price on Amazon