E8
Kyvol Main Brush Motor Overload / Blockage

Robot vacuum shows E8 and stops; main roller brush is not turning.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Main roller brush clogged with hair or debris, Brush bearings seized, Brush motor belt (if used) broken or slipped, Main brush motor failure

How to Fix / Troubleshooting

Safety: Turn OFF the robot and remove the dustbin before working on the brush.

  • 1. Remove the main brush:
    • Open the brush guard latch on the underside.
    • Lift out the main roller brush.
  • 2. Clean thoroughly:
    • Cut away hair and threads from the brush bristles and ends.
    • Remove the end caps (if removable) and clear hair from the bearings.
  • 3. Inspect brush cavity:
    • Check inside the brush housing for debris or foreign objects.
    • Rotate the brush motor shaft by hand; it should turn smoothly.
  • 4. Reassemble and test:
    • Reinstall the brush and close the guard securely.
    • Turn the robot ON and start a cleaning cycle; watch if the brush spins.
  • 5. If E8 persists:
    • Remove the bottom cover and inspect the main brush motor wiring.
    • If the motor is burnt, noisy, or seized, replace the main brush motor assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Brush Motor
Check Price on Amazon

We may earn a commission from links on this page.