Kyvol Battery Capacity Degradation

Robot vacuum runs for a very short time (5–15 minutes) and then returns to dock or shuts off, even after full charging.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aged lithium battery cells, Frequent partial charging cycles, High-temperature storage, Defective battery pack from manufacturing

How to Fix / Troubleshooting

Safety: Turn OFF the robot and avoid using a visibly swollen or leaking battery.

  • 1. Verify charge:
    • Charge the robot on the dock for at least 4–6 hours.
    • Ensure the charging indicator shows full charge.
  • 2. Measure runtime:
    • Start a cleaning cycle and time how long it runs before returning to dock or shutting down.
  • 3. Inspect battery:
    • Open the battery compartment and check for swelling or corrosion.
  • 4. Replace battery:
    • Purchase a genuine Kyvol-compatible replacement battery pack.
    • Disconnect the old pack, install the new one, and secure it properly.
    • Fully charge before first use.
  • 5. If runtime is still short:
    • The main board may be misreading battery levels; professional diagnosis is recommended.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Battery Pack
Check Price on Amazon

We may earn a commission from links on this page.