Laresar
Main Brush Drive Failure without Error
Robot vacuum's main brush does not spin, but suction works and no code is displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Main brush not seated correctly, Broken brush end cap, Stripped gear in brush motor, Loose motor connector
How to Fix / Troubleshooting
Safety: Turn off and flip the robot.
- Remove and reinstall brush: Take out the main brush, inspect the end caps and square/hex drive ends, then reinstall ensuring proper seating.
- Check for damage: Replace the brush if the ends are rounded or cracked.
- Test motor: Run the robot with the brush removed and observe if the drive socket spins. If not, the motor or gearbox is faulty.
- Replace module: Install a new main brush motor assembly if the drive does not operate.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Laresar Main Brush Motor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements