Shark Main Brush Not Agitating Properly

Robot vacuum leaves lines of debris or clumps behind it

Advertisements

Possible Causes

Worn main brush bristles, Brush not seated correctly, Brush guard damaged or warped, Debris blocking brush chamber

How to Fix / Troubleshooting

Safety: Turn OFF and invert the robot.

  • Remove and inspect brush: Check for worn, flattened, or missing bristles. Replace the brush if heavily worn.
  • Check brush guard: Ensure the guard closes fully and is not cracked or warped.
  • Clean chamber: Remove debris from the brush housing and edges where dirt may accumulate.
  • Reinstall correctly: Make sure the brush end caps are fully seated in their slots before closing the guard.