Thermostat displays E6 and does not respond to touch or app commands reliably
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off power to the HVAC system at the breaker before removing the thermostat from the wall.
- Step 1 – Power cycle: Turn off the furnace/air handler breaker for 2–3 minutes, then restore power. Check if E6 clears.
- Step 2 – Reseat thermostat: Gently pull the Amana smart thermostat off the wall plate and then firmly snap it back into place, ensuring all pins align and seat fully.
- Step 3 – Check 24V supply: With power on and using a multimeter (advanced users), measure voltage between R and C at the thermostat terminals. It should be around 24 VAC. If voltage is low or unstable, the issue may be with the Amana furnace/air handler transformer or control board.
- Step 4 – Factory reset: Use the thermostat’s settings menu to perform a factory reset (note: this will erase schedules and Wi‑Fi settings). After reset, reconfigure and see if E6 returns.
- Step 5 – Replace thermostat: If E6 persists after reset and power verification, the internal electronics are likely faulty. Replace the thermostat with a compatible Amana smart thermostat.
When to call a professional: If low or unstable 24V power is detected, an HVAC technician should inspect the Amana control board and transformer.