Possible Causes
Humidifier not enabled in installer settings, Incorrect humidity setpoint, Wiring to HUM terminals incorrect, Humidifier power not present
How to Fix / Troubleshooting
Safety: Turn off power to the furnace and humidifier before working on wiring.
- Enable humidifier: In installer settings, ensure the humidifier accessory is enabled and configured for the correct type.
- Set humidity target: Set a realistic humidity target (e.g., 35–45% in winter). If the target is too low, the humidifier may never run.
- Check HUM wiring: Verify that the humidifier solenoid or control relay is wired to the correct HUM or accessory terminals on the furnace board or thermostat, per American Standard diagrams.
- Verify humidifier power: Ensure the humidifier has its required power source (24V or 120V) and that any inline transformer is functioning.