E02
Atlantic
Internal Room Temperature Sensor Failure
Thermostat shows E02 and does not detect the indoor temperature correctly (reads -- or extreme values).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted NTC room sensor on display board, Damaged sensor trace on UI PCB, Moisture ingress into sensor area, Firmware miscalibration of sensor input
How to Fix / Troubleshooting
Safety first: Turn off power to the thermostat/HVAC at the breaker before removing the unit from the wall.
- Step 1 – Power cycle: Remove the thermostat from its wall base (if modular) or turn it off via the menu, wait 60 seconds, then restore power. Check if E02 clears.
- Step 2 – Check installation location: Ensure the thermostat is not installed above a radiator, in direct sunlight, or near drafts. Extreme localized heat or cold can cause readings that appear faulty, though they usually do not trigger E02.
- Step 3 – Inspect internal sensor: With power off, gently remove the front cover. Locate the small NTC thermistor on the user interface PCB (often a small bead or epoxy‑coated component near ventilation slots). Check for broken leads or contamination (dust, paint, condensation).
- Step 4 – Clean and dry: If there is visible moisture or dust, lightly blow out dust with dry air and allow the unit to dry completely. Do not use water or aggressive cleaners.
- Step 5 – Sensor test (advanced): Using a multimeter on resistance mode, measure across the NTC sensor leads (with the thermostat disconnected). Compare the resistance to Atlantic’s NTC curve (commonly ~10 kΩ at 25°C). An open circuit or near‑zero ohms indicates a failed sensor.
- Step 6 – Replace module: If the sensor is integrated and not separately replaceable, replace the thermostat front/user interface module or the entire thermostat assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Room Temperature NTC Sensor on UI PCB
Check Price on Amazon
We may earn a commission from links on this page.