Bosch EasyControl
Zone Demand Not Propagating to Boiler
Bosch EasyControl does not turn on heating for certain rooms controlled by Bosch Smart Radiator Thermostats, even when those rooms are cold.
Advertisements
Possible Causes
Zone not configured to call for heat, Radiator thermostat not linked to EasyControl correctly, Minimum system demand threshold not reached, Faulty radiator thermostat actuator
How to Fix / Troubleshooting
Safety first: Low risk; mainly app configuration and battery replacement.
- 1. Check zone settings: In the app, ensure each room with a Smart Radiator Thermostat is configured to request heat from the boiler, not just regulate locally.
- 2. Verify pairing: Remove and re-add the problematic radiator thermostat to the EasyControl system.
- 3. Observe valve movement: During a heat request, check that the radiator valve pin moves and that the radiator warms when the boiler is running.
- 4. Replace device: If the actuator does not move despite commands, replace the Smart Radiator Thermostat.
Professional help: For complex multi-zone issues, a heating engineer or Bosch support can review the configuration.