Bosch EasyControl Under-Reading Room Temperature

Bosch EasyControl shows much lower room temperature than actual, causing the boiler to run almost constantly.

Advertisements

Possible Causes

Cold draught behind thermostat, Mounted on external wall, Sensor calibration drift, Wiring hole not sealed behind wall plate

How to Fix / Troubleshooting

Safety first: Isolate power before removing the thermostat from the wall.

  • 1. Compare with thermometer: Place a separate thermometer near the EasyControl and compare readings.
  • 2. Seal wall opening: Remove the EasyControl and seal any large gaps in the wall box or cable entry with non-combustible filler to stop cold air from behind.
  • 3. Relocate if necessary: If installed on an external wall or in a draughty hallway, consider moving it to a more central, representative room.
  • 4. Apply small offset: Use the installer menu to apply a minor temperature offset if the difference is consistent and small.

Professional help: If readings remain significantly wrong, the internal sensor may be faulty and the unit should be replaced.