C17
Bosch EasyControl Outdoor Temperature Sensor Fault

Bosch EasyControl displays error C17 and indicates that the external temperature sensor (for weather compensation) is not detected or faulty.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected or damaged outdoor sensor cable, Failed NTC outdoor sensor, Incorrect sensor type fitted, Short-circuit or open-circuit in sensor wiring

How to Fix / Troubleshooting

Safety first: Isolate power to the boiler and any external sensor circuits before working on wiring.

  • 1. Locate sensor: Find the Bosch outdoor temperature sensor mounted on an external wall, usually north-facing and away from direct sun.
  • 2. Inspect physically: Check for physical damage, water ingress, or loose cable glands. Ensure the cable is firmly connected at both the sensor and boiler/EasyControl interface.
  • 3. Test resistance: With power off, disconnect the sensor and measure its resistance with a multimeter. Compare to the Bosch temperature/resistance chart. Replace if readings are out of range.
  • 4. Check wiring continuity: Test each conductor from sensor to boiler for continuity and absence of shorts.

Professional help: If wiring and sensor are good but C17 persists, the boiler’s sensor input or EasyControl interface may be faulty and should be checked by a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Bosch outdoor temperature sensor
Check Price on Amazon