Bosch No Heat Call from Thermostat

Thermostat powers on but does not call for heat even when room is cold and setpoint is higher than room temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect system type configuration (set to cooling only), Heat call (W) wire not connected or broken, Heat disabled in installer settings, Faulty heat relay output on thermostat

How to Fix / Troubleshooting

Safety: Turn off power to the HVAC system before changing wiring.

  • Check mode and setpoint: Ensure the thermostat is in HEAT or AUTO mode and the setpoint is above room temperature.
  • Verify wiring: Confirm the W (or W1) wire is connected at both the thermostat and the Bosch boiler/furnace control board.
  • Installer settings: In the advanced menu, verify that heating is enabled and that the correct system type (heat pump vs. conventional) is selected.
  • Bypass test: At the control board, with power on, temporarily jumper R to W. If the boiler/furnace starts, the issue is likely with the thermostat or its wiring.
  • Replace thermostat if needed: If wiring is intact and equipment responds to a jumper but not to the thermostat, the thermostat’s heat output may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Bosch Smart Thermostat Main Control Assembly
Check Price on Amazon