E6
Bryant Heat Pump Configuration or Communication Fault

Thermostat displays E6 and will not allow heat pump operation or shows limited heat pump options.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect equipment configuration in Bryant smart thermostat setup, Missing or miswired Y/Y2 or O/B communication to heat pump, Incompatible outdoor unit with Evolution/Connex thermostat, Faulty heat pump control board communication circuit

How to Fix / Troubleshooting

Safety first: Turn off power to indoor and outdoor units at the breakers before changing wiring.

Steps to troubleshoot:

  • 1. Verify equipment type in setup: Enter the thermostat’s installer or advanced setup menu and confirm that the system type is correctly set to heat pump with the proper number of stages and accessories.
  • 2. Check low-voltage wiring: Confirm that the heat pump reversing valve (O/B), compressor (Y/Y2), and common (C) are correctly wired at the indoor control board and outdoor unit. Tighten any loose connections.
  • 3. Confirm Bryant compatibility: Ensure the outdoor heat pump is a Bryant Evolution/Connex-compatible model if using a communicating thermostat. Non-communicating units may require a different thermostat or control strategy.
  • 4. Power cycle system: After correcting configuration or wiring, shut off power for 2–3 minutes, then restore and check if E6 clears.
  • 5. Professional service: If E6 persists with correct configuration and wiring, a technician should test the outdoor control board and communication circuits.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Bryant Heat Pump Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements