Danfoss Ally
Boiler Stuck On / Ghost Demand
Boiler or heat source runs continuously even when all Danfoss Ally thermostats show no heat demand.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or welded relay contacts in thermostat or boiler interface, Incorrect wiring bypassing thermostat, External demand signal from another controller, Misconfigured system integration
How to Fix / Troubleshooting
Safety first: Isolate power to the boiler and control circuits before inspection.
Steps:
- Identify control path: Determine which device (Ally thermostat, boiler interface, or other controller) is actually switching the boiler.
- Inspect relay contacts: If using an external relay or contactor controlled by Ally, check for welded contacts and replace the faulty relay.
- Check wiring: Ensure there is no permanent live feed bridging the boiler’s control input.
- Test with thermostat disconnected: Temporarily disconnect the thermostat control wires at the boiler. If the boiler still runs, the fault is in the boiler or another controller, not the Ally system.