CF
Danfoss Ally
Configuration Fault / Parameter Error
Display shows 'CF' or configuration error; thermostat does not follow expected heating mode or sensor selection.
Advertisements
Possible Causes
Incorrect sensor mode (room/floor) selected, Wrong control type (PWM/on‑off) configured, Incompatible system type chosen in setup, Corrupted configuration data
How to Fix / Troubleshooting
Safety first: For wired thermostats, isolate power before removing covers.
Steps:
- Review installation manual: Check the Danfoss Ally manual for the correct configuration parameters for your system (radiator, underfloor heating, electric floor, etc.).
- Enter installer menu: Access the installer or advanced settings menu and verify sensor selection (internal, external, or combined), control algorithm, and maximum floor temperature limits.
- Correct parameters: Adjust settings to match the actual wiring and heating type. Save and exit the installer menu.
- Factory reset if needed: If the error persists, perform a factory reset and repeat the guided setup from the Ally app.
Advertisements
Repair Difficulty
Easy
2/5