E2
Danfoss Ally
External Temperature Sensor Error
Thermostat shows E2 and cannot correctly regulate room temperature; display may show dashes instead of temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
External floor/remote NTC sensor open circuit, External floor/remote NTC sensor short circuit, Loose or reversed sensor wiring at thermostat terminals, Damaged sensor cable
How to Fix / Troubleshooting
Safety first: Switch off power to the thermostat at the breaker before touching any wiring.
Steps:
- Verify sensor connection: Remove the thermostat from the wall plate and check that the external sensor wires are firmly clamped in the correct terminals as per the Danfoss Ally wiring diagram.
- Inspect cable: Look for cuts, crushed sections, or signs of moisture in the sensor cable, especially where it enters the wall or floor.
- Check resistance: Using a multimeter, measure resistance across the sensor leads (with power off). Compare the reading to the Danfoss NTC sensor resistance table at room temperature (typically ~10kΩ at 25°C for many Danfoss sensors). If reading is near 0Ω (short) or infinite (open), the sensor is faulty.
- Reconnect or replace: Reseat the wires and tighten the terminals. If the sensor is defective, replace it with a Danfoss‑approved NTC floor/remote sensor of the correct value.
- Reset thermostat: Restore power and clear the error by rebooting or performing a factory reset if required by the manual.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Danfoss NTC Floor/Remote Temperature Sensor
Check Price on Amazon