Danfoss Ally
Underheating / Insufficient Heat Output
Room never reaches the set temperature; it stays several degrees below the setpoint even though the thermostat calls for heat.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flow temperature too low from boiler, Radiator or underfloor circuit partially air‑locked, Thermostat limiting maximum floor temperature, Incorrect valve balancing or small radiator size
How to Fix / Troubleshooting
Safety first: For any boiler adjustments, follow boiler manufacturer safety instructions or contact a heating professional.
Steps:
- Check other rooms: If all rooms are cold, the boiler flow temperature or system pressure may be too low; check boiler settings and pressure gauge.
- Bleed radiators: Use a radiator key to bleed trapped air from radiators, starting with the highest ones. Protect floors from water.
- Review floor temp limits: For underfloor heating, check the Ally thermostat’s maximum floor temperature setting and increase slightly if safe and within flooring manufacturer limits.
- Balance system: Ensure lockshield valves on radiators are not nearly closed, restricting flow. Adjust balancing if necessary.
Advertisements
Repair Difficulty
Medium
3/5