Temperature Calibration Offset
Thermostat shows a much higher or lower temperature than the actual room temperature by a consistent offset.
Advertisements
Possible Causes
Thermostat installed in atypical location (cold wall, draught), Internal sensor offset, Heat from electronics affecting reading, No calibration offset set in software
How to Fix / Troubleshooting
Safety first: No hazardous work required.
Steps:
- Compare with reference: Place a reliable thermometer near the thermostat and compare readings after 30 minutes.
- Adjust offset: If supported, use the Ally app or thermostat installer menu to apply a temperature offset to match the reference.
- Improve location: If the thermostat is on an exterior wall or near a draught, relocate it to a more representative position.
- Replace if extreme: If the offset is very large (>5°C) and cannot be corrected, the sensor may be defective; replace the thermostat.
Advertisements
Repair Difficulty
Very Easy