E20
Delta Dore Temperature Sensor Calibration Out of Range

E20 displayed and thermostat reports a sensor calibration error; measured temperature is offset significantly.

Advertisements

Possible Causes

Incorrect manual calibration offset, Sensor drift beyond allowed range, Firmware bug, Damaged NTC sensor

How to Fix / Troubleshooting

Safety first: No special risk for calibration; avoid opening mains-powered units with power on.

  • Compare with reference: Place a reliable thermometer near the thermostat and compare readings.
  • Reset calibration: In the menu, go to Settings > Temperature calibration and reset the offset to 0 or factory default.
  • Re-enter small offset: If needed, apply a small correction (e.g. ±1–2°C) and verify that E20 clears.

If E20 persists and the reading is far from reality, the internal sensor is likely defective and the thermostat should be replaced.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Delta Dore Thermostat Internal NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements