Drayton
Underheating / Insufficient Heat Output
Room never reaches the set temperature; thermostat shows demand but room stays cold.
Advertisements
Possible Causes
Incorrect minimum on-time or cycle rate settings, Thermostat incorrectly configured for underfloor vs radiators, Stuck TRVs on radiators in thermostat room, Faulty room sensor reading too high
How to Fix / Troubleshooting
Safety first: Isolate mains before working on any valves or wiring.
- Check radiator/TRVs: Ensure radiators in the thermostat room are fully open and TRVs are not stuck. Free any stuck TRV pins carefully.
- Verify control mode: In the Drayton thermostat or Wiser app, confirm that the control type (radiator vs underfloor) and cycle rate are set correctly for your system.
- Compare temperatures: Use a separate thermometer to compare with the thermostat reading. If the thermostat reads significantly higher, the sensor may be faulty or poorly located.
- Relocate or replace sensor: Move the thermostat to a more representative location or replace the thermostat if the sensor is inaccurate.