Thermostat displays E2 and shows incorrect or no room temperature reading
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Switch off power to the furnace/air handler at the breaker before removing the thermostat.
Steps to troubleshoot:
- 1. Check environment: Ensure the thermostat is not installed where it can be exposed to steam, direct moisture, or dripping water (e.g., near showers or humidifiers). Dry any visible moisture with a soft cloth.
- 2. Power cycle: Turn off the HVAC breaker for 2–3 minutes, then restore power. Observe if E2 clears.
- 3. Remove thermostat from wall plate: Gently pull the Emerson thermostat straight off the sub-base. Inspect the back of the thermostat for corrosion, moisture, or debris around the vent slots where the sensor resides.
- 4. Clean carefully: If light dust or debris is present, use a can of dry compressed air to blow out the vents. Do not use liquids or aggressive cleaners.
- 5. Factory reset: Perform a factory reset from the settings menu. Reconfigure Wi‑Fi and system type, then check if E2 returns.
- 6. Persistent E2: A shorted sensor or PCB trace usually requires replacing the thermostat; internal sensor components are not serviceable.
When to call a professional: If the thermostat is in a high-humidity environment or shows corrosion, consult an HVAC technician to relocate and replace the thermostat.
Repair Difficulty
Required Part