CF
Eurotronic Calibration Mode / Calibration Failure

Thermostat shows 'CF' or 'CAL' and does not control heating until calibration completes or fails.

Advertisements

Possible Causes

Valve stroke calibration not completed, Obstructed valve pin, Low battery during calibration, Incorrect valve adapter installed

How to Fix / Troubleshooting

Safety: Let radiators cool before handling TRVs.

  • Wait for completion: If 'CF' appears briefly, allow the calibration cycle to finish. Do not remove batteries or disturb the valve during this process.
  • Check batteries: Install fresh batteries before starting calibration to avoid mid-cycle failure.
  • Verify adapter: Confirm that the correct Eurotronic adapter ring is used for your radiator valve type and that it is firmly tightened.
  • Free valve pin: Remove the TRV head and manually move the valve pin in and out until it moves smoothly. Reinstall the head and restart calibration.
  • Replace drive: If calibration fails repeatedly, the internal motor or position sensor may be defective. Replace the TRV head.