A01
Ferroli
Ignition Failure Lockout (Boiler Communication)
Thermostat display shows A01 and boiler does not ignite when there is a call for heat.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Boiler in A01 lockout due to failed ignition, Open or shorted OT (OpenTherm) communication cable between Ferroli smart thermostat and boiler, Incorrect thermostat heat demand configuration, Faulty boiler main PCB preventing response to thermostat
How to Fix / Troubleshooting
Safety first: You are working with a control that communicates with a gas boiler. Do not open the boiler casing unless you are a qualified technician. You may work on low‑voltage thermostat wiring only with power isolated.
- Reset the boiler and thermostat:
- Turn the boiler off at the main switch and isolate power for 30 seconds.
- Turn the Ferroli smart thermostat off (if it has a power button) or remove it from its base for 30 seconds.
- Restore power to the boiler, then refit/power the thermostat and check if A01 clears.
- Check communication wiring:
- Isolate power to the boiler and thermostat.
- Locate the OT/OpenTherm or BUS terminals on the boiler and on the Ferroli smart thermostat receiver/base.
- Verify the two‑core cable is firmly clamped, not reversed (if polarity is required by your model), and not damaged or pinched.
- Tighten any loose terminal screws.
- Verify thermostat settings:
- In the thermostat menu, confirm the control mode is set to OpenTherm/Bus (not simple on/off) if your boiler supports it.
- Ensure the heating schedule is active and the setpoint is above room temperature.
- If A01 persists:
- The boiler may have a genuine ignition fault (electrode, gas valve, or PCB). Do not attempt to repair the boiler yourself.
- Contact a qualified Ferroli service technician and report that the thermostat shows A01 and the boiler is in ignition lockout.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Ferroli OpenTherm Room Thermostat Cable
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements