Possible Causes

Heating schedule set to OFF or holiday mode active, Thermostat in manual OFF or summer mode, Incorrect system type selected (e.g., cooling only), Internal relay or BUS output failure

How to Fix / Troubleshooting

Safety first: Work on low‑voltage controls only; do not open the boiler.

  • Check operating mode:
    • Ensure the thermostat is in HEAT mode, not OFF or COOL.
    • Disable holiday or eco modes that may suppress heating.
  • Review schedule:
    • Confirm that the current time period is programmed for a temperature above room temperature.
  • Force manual demand:
    • Set the thermostat to a high manual setpoint (e.g., 25 °C) and observe if the boiler starts.
  • Check wiring/receiver:
    • Verify that the receiver is powered and paired.
    • If using relay control, check that the relay closes when there is demand (listen for a click).
  • If still no demand:
    • The thermostat output stage may be faulty; replace the Ferroli smart thermostat or receiver.