Fibaro No Output to Heating Load

Thermostat calls for heat (indicator shows heating) but underfloor heating remains cold

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open circuit in underfloor heating mat or cable, Loose connection at thermostat load terminals, Failed output relay/triac in Fibaro thermostat, Disconnected junction box between thermostat and heating element

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before touching any wiring. Underfloor heating circuits are mains‑voltage in many regions.

Steps to diagnose no‑heat output:

  • 1. Confirm thermostat is calling for heat:
    • Set the thermostat to a high temperature and verify the heating indicator or relay click is present.
  • 2. Check load wiring at thermostat:
    • With power off, remove the thermostat.
    • Inspect the load (heating) terminals for loose or disconnected wires.
    • Tighten terminal screws as needed.
  • 3. Measure output voltage:
    • Restore power and, if you are qualified, measure voltage at the load terminals when there is a heat call.
    • No voltage indicates a failed relay/triac or internal fault.
  • 4. Inspect junction boxes and heating cable:
    • Trace the cable from the thermostat to any junction boxes.
    • Check for loose connections or damaged cables.
  • 5. Test heating element resistance:
    • With power off and cables disconnected, measure resistance of the heating mat or cable.
    • Infinite resistance indicates a break in the element.

When to call a professional: Breaks in underfloor heating elements usually require a specialist with cable fault‑finding equipment. A failed thermostat output stage should be replaced by an electrician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Fibaro Smart Thermostat Relay Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements