E03
Geo
W (Heat Call) Circuit Open or Short
Thermostat shows E03 and will not control heating; system remains off even when heat is requested.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose W terminal connection at Geo wall plate, Broken W conductor in thermostat cable, Shorted W wire to C or ground, Failed relay on Geo main control PCB
How to Fix / Troubleshooting
Safety first: Turn off power to the HVAC system at the breaker before removing covers or moving wires.
- Step 1 – Inspect thermostat connections: Remove the Geo thermostat and check that the W (or W1) wire is fully inserted and clamped in the W terminal on the wall plate. Tighten if loose.
- Step 2 – Inspect furnace connections: At the furnace/air handler control board, verify the W wire is firmly attached to the W terminal and not corroded or broken.
- Step 3 – Continuity test: With power off and both ends of the W wire disconnected, use a multimeter in continuity mode between the W conductor at the thermostat end and the W conductor at the furnace end. If open, the cable is damaged and a spare conductor should be used or the cable replaced.
- Step 4 – Check for shorts: Inspect the thermostat cable along its run (if accessible) for staples or sharp bends that may have pierced the insulation. A short between W and C or W and R can trigger E03.
- Step 5 – Test furnace response: With power on, temporarily jumper R to W at the furnace control board. If the heat starts, the furnace is fine and the issue is in the thermostat or wiring. Remove the jumper after testing.
- Step 6 – Replace thermostat head: If wiring checks out and the furnace responds to an R‑W jumper, the W relay on the Geo thermostat PCB may be failed. Replace the thermostat head unit.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
W Heat Call Circuit / Main Control PCB
Check Price on Amazon