F.13
Glow-worm
Outdoor Sensor Fault
Thermostat displays F.13 and outdoor temperature is not shown
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed Glow‑worm outdoor NTC sensor, Open‑circuit or shorted outdoor sensor cable, Sensor exposed to direct sunlight or water ingress, Incorrect sensor type configured
How to Fix / Troubleshooting
Safety: Isolate boiler power before working on wiring. The outdoor sensor is low voltage but may be routed alongside mains cables.
Steps:
- Locate the outdoor sensor on an external wall, ideally north‑facing. Check that it is securely mounted and not directly in sun or near flue terminals.
- Inspect the sensor housing for cracks or water ingress. Replace if the enclosure is compromised.
- With power off, disconnect the sensor and measure its resistance. Compare to the Glow‑worm NTC chart for the current outdoor temperature.
- Check the thermostat or system controller configuration to ensure outdoor compensation is enabled only if a sensor is installed and that the correct sensor type is selected.
Remedy:
- Replace the outdoor sensor if resistance is out of specification or if the housing is damaged.
- Repair or replace any damaged cable and ensure joints are weatherproof.
- After repair, restore power and confirm that the thermostat displays a realistic outdoor temperature and that F.13 clears.