Glow-worm
Poor Control Tuning / Location Issue
Thermostat shows very slow response; rooms overshoot set temperature by several degrees
Advertisements
Possible Causes
Thermostat installed in draughty or atypical location, Incorrect control algorithm (on/off vs modulating) selected, Oversized boiler with no modulation enabled, Disabled optimisation features
How to Fix / Troubleshooting
Safety: Only configuration and relocation are involved.
Steps:
- Check thermostat location: it should be on an internal wall, about 1.5 m above floor level, away from direct sunlight, radiators, and external doors.
- In the installer menu, ensure the control mode is set to modulating (eBus/OpenTherm) if supported by your Glow‑worm boiler, rather than simple on/off.
- Enable optimisation features such as load compensation, weather compensation (if outdoor sensor fitted), and optimum start/stop if available.
- After changes, monitor room temperature over several days and fine‑tune any available control parameters (cycle rate, hysteresis) according to the manual.
Remedy:
- If overshoot persists despite correct setup and location, consult a heating engineer to check boiler sizing and system balancing.