E14
Gosund
Real‑Time Clock (RTC) / Time Sync Failure
E14 error and thermostat shows incorrect time or cannot maintain time after power loss
Advertisements
Possible Causes
Failed RTC crystal or chip, Dead or missing backup capacitor/battery, Blocked NTP time sync due to network issues, Firmware bug in timekeeping
How to Fix / Troubleshooting
Safety: No high‑voltage exposure for this fault; do not open the unit unless necessary.
- Step 1 – Enable network time:
- Ensure the thermostat is connected to Wi‑Fi and the Gosund cloud.
- In settings, enable automatic time synchronization if available.
- Step 2 – Check time zone:
- Verify the correct time zone and daylight saving settings in the app.
- Step 3 – Power stability:
- Confirm that the thermostat is not losing 24VAC power frequently (see E06 steps).
- Step 4 – Firmware update:
- Update firmware via the Gosund app to correct any known RTC bugs.
- Step 5 – Replace thermostat if RTC hardware is bad:
- If E14 persists and time drifts significantly even with stable power and network, the RTC hardware on the main PCB is likely defective.
- Replace the thermostat.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Real‑Time Clock Circuit (Crystal and RTC IC on Main Control PCB)
Check Price on Amazon