No Cool Call from Thermostat
Thermostat has power but will not turn on cooling when room is above setpoint
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose or broken Y (or Y1) wire, Misconfigured system type, Failed cooling relay on thermostat, Open float switch or safety in condensate line
How to Fix / Troubleshooting
Warning: Turn off power to indoor and outdoor units before wiring work.
- Step 1 – Verify settings:
- Ensure the thermostat is set to Cool mode and the setpoint is below room temperature.
- Step 2 – Inspect Y wiring:
- Check that the Y/Y1 wire is secure at both thermostat and furnace/air handler board.
- Inspect any float switches or safety devices in series with Y for tripping.
- Step 3 – Test system response:
- At the furnace board, jumper R to Y; if the outdoor unit starts, the thermostat or wiring is at fault.
- Step 4 – Measure Y output:
- With a cool call active, measure voltage between Y and C at the thermostat; should be ~24VAC.
- If no voltage, the cooling relay is likely defective.
- Step 5 – Replace thermostat if Y output is bad:
- Replace the thermostat if it cannot energize Y with a cool call.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cool Call Relay (Y Output) on Main Control PCB
Check Price on Amazon