Gosund No Power to Thermostat

Thermostat screen is completely blank and HVAC system does not respond

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No 24VAC from furnace transformer, Blown low‑voltage fuse on furnace board, Disconnected R or C wire at thermostat or furnace, Defective internal power supply on thermostat

How to Fix / Troubleshooting

Danger: HVAC systems contain high voltage. Turn off power at the breaker before opening any panels.

  • Step 1 – Check breakers and furnace switch:
    • Verify that the furnace/air handler breaker is ON and the service switch is not off.
  • Step 2 – Inspect furnace control board fuse:
    • Turn off power, open the blower compartment, and locate the control board.
    • Check the low‑voltage blade fuse; replace if blown with the same rating.
  • Step 3 – Verify R and C voltage:
    • With power on, measure AC voltage between R and C at the furnace board and at the thermostat wall plate; should be ~24VAC.
    • If present at the board but not at the thermostat, repair or replace the thermostat cable.
  • Step 4 – Check thermostat connections:
    • Ensure R and C wires are firmly connected at the thermostat base.
  • Step 5 – Replace thermostat if powered but dead:
    • If 24VAC is present at the thermostat but the screen remains blank, the internal power circuit or display is likely failed; replace the thermostat.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB / Internal Power Supply
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements