Er4
Heatit Overtemperature Limit Sensor Triggered

Display shows Er4 and thermostat output is locked off

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Floor temperature exceeded configured max limit, External limit sensor detecting too high temperature, Incorrect max floor temp setting, Sensor placed too close to heating cable

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker if you need to access wiring or sensors.

Steps to troubleshoot:

  • 1. Check temperature limits:
    • Enter the installer menu and review max floor temperature and any limit sensor settings.
    • Set max floor temp to a safe but realistic value (e.g. 27–35°C depending on floor type).
  • 2. Allow system to cool:
    • Turn off heating for several hours to let the floor cool.
    • Once cooled, Er4 should clear automatically.
  • 3. Verify sensor placement:
    • If possible, check that the floor sensor is not directly touching the heating cable.
    • Reposition sensor centrally between heating runs.
  • 4. Check floor covering compatibility:
    • Ensure the floor covering (e.g. wood, vinyl) is approved for the set temperature.
    • Reduce max floor temp if the covering is sensitive.
  • 5. Replace faulty sensor:
    • If the sensor reports high temperature even when floor is cool, replace the Heatit NTC floor sensor or external limit sensor.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Heatit NTC Floor Sensor (10k) or External Limit Sensor
Check Price on Amazon