Er5
Heatit External Room Sensor Out of Range

Display shows Er5 and thermostat cannot control external room sensor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

External sensor cable extended too far, Wrong cable type causing resistance error, Sensor installed in draft or sun, Defective external sensor element

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before working on sensor wiring.

Steps to troubleshoot:

  • 1. Inspect external sensor location:
    • Ensure the sensor is mounted at about 1.5 m height, away from direct sunlight, drafts, and heat sources.
  • 2. Check cable length and type:
    • Verify that the cable length does not exceed the maximum specified in the Heatit manual.
    • Use twisted pair or recommended cable type to minimize resistance and noise.
  • 3. Measure sensor resistance:
    • Disconnect the sensor at the thermostat and measure resistance.
    • Compare with the expected NTC curve; replace if out of range.
  • 4. Reconfigure sensor type:
    • In the installer menu, confirm the correct external sensor type is selected.
  • 5. Replace sensor if faulty:
    • Install a new Heatit external room sensor and reconnect.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Heatit External Room Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.