Heatit Underheating / Insufficient Output

Thermostat shows correct temperature but floor feels cold

Advertisements

Possible Causes

Setpoint too low, Max floor temperature limit too low, Heating cable wattage insufficient, Floor sensor mispositioned deeper in screed

How to Fix / Troubleshooting

Safety first: Configuration changes can be made without opening the unit.

Steps to troubleshoot:

  • 1. Increase setpoint:
    • Raise the room or floor setpoint gradually and monitor comfort.
  • 2. Check max floor temperature:
    • In the installer menu, verify that max floor temp is not set too low (e.g. 20–22°C).
    • Increase within safe limits for your floor covering.
  • 3. Verify heating cable power:
    • Check the installed floor heating wattage per m² against room heat loss; low wattage may not be sufficient.
  • 4. Sensor depth:
    • If the sensor is buried too deep, it may read warmer than the surface; consider using room sensor control with floor limit.
Advertisements

Repair Difficulty

Easy 2/5