Honeywell Home Stuck Fan Relay or Miswired G Circuit

Thermostat fan runs continuously even when set to Auto and no call for heat/cool

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck fan relay on furnace board, G wire shorted to R, Fan set to circulate mode in thermostat, Incorrect wiring at thermostat

How to Fix / Troubleshooting

Safety: Turn off power to the furnace/air handler before inspecting wiring.

  • Check fan setting: Ensure the thermostat fan mode is set to Auto, not On or Circulate.
  • Inspect G wiring: At the thermostat and furnace board, verify that the G wire is not touching R or any other terminal.
  • Test relay (advanced): With power off, remove the G wire from the furnace board. Restore power; if the fan still runs, the fan relay is stuck closed and the control board may need replacement.
  • Replace control board: If the fan relay is confirmed stuck, replace the furnace control board or fan relay module.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Furnace Control Board
Check Price on Amazon