Honeywell Home Equipment Protection Delay or Safety Lockout

Thermostat shows 'Waiting for Equipment' for an extended period

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Built‑in compressor or burner delay, Equipment in safety lockout, Float switch or high‑pressure switch open, Low‑voltage fuse blown

How to Fix / Troubleshooting

Safety: If you suspect a gas or refrigerant leak, contact a professional immediately.

  • Allow standard delay: Wait at least 5–10 minutes to see if the system starts after the protection delay.
  • Check equipment status lights: Inspect the furnace/air handler and outdoor unit for diagnostic LEDs or error codes and refer to their manuals.
  • Inspect safety switches: Check condensate float switches, pressure switches, and door interlocks to ensure they are closed.
  • Reset equipment: Turn power off to the furnace/air handler and outdoor unit for 5 minutes, then restore power and observe operation.
  • Call technician: Persistent 'Waiting for Equipment' indicates an equipment fault that should be diagnosed by an HVAC professional.
Advertisements

Repair Difficulty

Hard 4/5