Possible Causes
Built‑in compressor or burner delay, Equipment in safety lockout, Float switch or high‑pressure switch open, Low‑voltage fuse blown
How to Fix / Troubleshooting
Safety: If you suspect a gas or refrigerant leak, contact a professional immediately.
- Allow standard delay: Wait at least 5–10 minutes to see if the system starts after the protection delay.
- Check equipment status lights: Inspect the furnace/air handler and outdoor unit for diagnostic LEDs or error codes and refer to their manuals.
- Inspect safety switches: Check condensate float switches, pressure switches, and door interlocks to ensure they are closed.
- Reset equipment: Turn power off to the furnace/air handler and outdoor unit for 5 minutes, then restore power and observe operation.
- Call technician: Persistent 'Waiting for Equipment' indicates an equipment fault that should be diagnosed by an HVAC professional.