iComfort
Dehumidifier Control Failure
Thermostat does not detect or control whole‑home dehumidifier
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dehumidifier not wired to correct terminals, Dehumidifier not powered, Incorrect dehumidifier configuration, Failed dehumidifier output relay
How to Fix / Troubleshooting
Safety first: Turn off power to the HVAC system and dehumidifier before working on wiring.
- Step 1 – Confirm configuration: In installer setup, verify that a dehumidifier is enabled and the correct control method is selected.
- Step 2 – Inspect wiring: Ensure the dehumidifier control wires are on the correct iComfort dehumidifier terminals and that polarity is correct if required.
- Step 3 – Verify dehumidifier operation: Manually start the dehumidifier using its onboard controls (if available) to confirm it works independently.
- Step 4 – Test control signal: Command dehumidification from the thermostat and measure for control voltage at the dehumidifier terminals.
- Step 5 – Replace thermostat/interface: If no control signal is present despite correct setup, the dehumidifier output circuit may be defective and the thermostat or interface module should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
iComfort Dehumidifier Control Output (Thermostat/Interface)
Check Price on Amazon