Thermostat causes boiler to short-cycle (frequent on/off) even when room not at setpoint
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Cycle rate set too high, Proportional band too narrow, Boiler minimum run time not respected, Oversized boiler with low modulation
How to Fix / Troubleshooting
Safety first: No internal boiler work should be done by unqualified persons.
Steps:
- 1. Adjust cycle rate: In the installer settings, reduce the cycle rate (e.g. from 6 cycles/hour to 3 cycles/hour) appropriate for radiators or underfloor heating.
- 2. Increase hysteresis: If available, widen the temperature differential so the thermostat does not switch off with very small changes.
- 3. Enable OpenTherm (if supported): Use OpenTherm modulation instead of simple on/off to reduce cycling.
- 4. Check boiler settings: Ask a heating engineer to set a suitable minimum run time and anti‑cycle time on the Ideal boiler.
Advertisements
Repair Difficulty
Medium
3/5