Ideal No Heat Call from Thermostat

Thermostat screen on but boiler does not fire for heating demand

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect wiring to boiler or wiring centre, Thermostat set to 'Off' or low setpoint, Faulty CH relay or triac, RF receiver not responding to thermostat

How to Fix / Troubleshooting

Safety first: Isolate mains power before accessing wiring or receivers.

Steps:

  • 1. Check settings: Ensure the thermostat is in 'Heat' mode and the set temperature is above current room temperature. Check schedules are not in an 'Off' period.
  • 2. Verify RF link (if wireless): Check the Ideal RF receiver LEDs. If the 'link' LED is off or flashing, re‑pair the thermostat and receiver as per the manual.
  • 3. Wiring centre test: At the wiring centre, with power off, confirm the thermostat CH call wire is correctly connected. With power on and a heat demand, measure for 230 V (or appropriate voltage) on the CH output.
  • 4. Manual boiler test: Briefly link live to the boiler's CH call terminal at the wiring centre. If the boiler fires, the issue is with the thermostat or its wiring.
  • 5. Replace thermostat or receiver: If wiring is correct and manual tests work, the thermostat or RF receiver output stage may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ideal RF Receiver / Smart Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements