E02
Immergas
Boiler Not Detected on BUS
Thermostat shows E02 and does not detect the boiler; remote control of heating and DHW is disabled
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Boiler not powered or in lockout, BUS terminals not enabled in boiler parameters, Incorrect thermostat type selected in boiler menu, Faulty thermostat main board
How to Fix / Troubleshooting
Safety: Switch off boiler power before opening its front panel. Only access user-level menus unless you are qualified.
- Step 1 – Check boiler status: Confirm the Immergas boiler is powered on and not in lockout. Reset the boiler if a lockout is active.
- Step 2 – Verify BUS activation: On the boiler control panel, enter the installer or advanced menu (refer to the boiler manual) and confirm that the external thermostat/BUS control is enabled.
- Step 3 – Confirm thermostat type: Some Immergas boilers require selecting the correct thermostat model (e.g., CARV2, SMARTECH, or specific smart thermostat) in the boiler configuration. Adjust if incorrect.
- Step 4 – Re-register device: If your thermostat is a wireless Immergas smart thermostat with a gateway, re-pair it following the manufacturer’s pairing procedure.
- Step 5 – Factory reset thermostat: Perform a factory reset on the thermostat (see user manual). Reconfigure language, Wi‑Fi, and boiler connection.
- Step 6 – Service call: If E02 persists, the thermostat main board or boiler control board may be defective. Contact an authorized Immergas technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Immergas smart thermostat main board
Check Price on Amazon