Immergas Call for Heat Not Reaching Boiler

Thermostat powers on but does not turn the boiler on; boiler remains in standby

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect wiring to boiler thermostat terminals, Thermostat configured in wrong control mode (BUS vs on/off), Open circuit in thermostat output contacts, Boiler parameter set to ignore external thermostat

How to Fix / Troubleshooting

Safety: Isolate mains power to the boiler before touching any wiring.

  • Step 1 – Verify demand: Increase the setpoint temperature well above room temperature and check if the thermostat indicates a heating demand (flame icon or similar).
  • Step 2 – Check wiring mode: Confirm whether your Immergas boiler is expecting a simple on/off contact or BUS communication, and wire the thermostat accordingly.
  • Step 3 – Inspect terminals: At the boiler, ensure the thermostat wires are connected to the correct terminals (e.g., TA, COM/NO, or BUS). Tighten any loose screws.
  • Step 4 – Test contact: For on/off systems, temporarily bridge the boiler thermostat terminals with a short wire. If the boiler starts, the issue is in the thermostat or its wiring.
  • Step 5 – Check boiler settings: In the boiler menu, confirm that external thermostat control is enabled and not overridden by internal programming.
  • Step 6 – Replace thermostat: If wiring and boiler settings are correct but no call for heat is sent, the thermostat output relay or BUS driver may be faulty.