Immergas No Power to Thermostat

Thermostat screen completely blank, no lights or response

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown low-voltage fuse on Immergas boiler control board, Disconnected thermostat power wires, Faulty external transformer (if used), Reversed polarity or short on power terminals

How to Fix / Troubleshooting

Safety: Turn off boiler power at the main switch before opening any covers. Low-voltage circuits are still powered from mains equipment.

  • Step 1 – Check boiler power: Confirm the boiler itself is powered and its display is on.
  • Step 2 – Inspect thermostat wiring: Remove the thermostat from the wall plate and verify that the power terminals (e.g., +/– or 24 V) have firmly connected wires.
  • Step 3 – Measure voltage: With a multimeter and appropriate skills, measure the voltage at the thermostat power terminals. If no voltage is present, trace back to the boiler or transformer.
  • Step 4 – Check boiler fuse: On the Immergas boiler control board, locate the low-voltage fuse feeding the thermostat circuit. Replace only with the same type and rating if blown.
  • Step 5 – Replace transformer: If an external 24 V transformer is used and no output is measured, replace it with a compatible unit.
  • Step 6 – Replace thermostat: If correct voltage is present at the thermostat but the screen remains blank, the thermostat is defective and must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Immergas boiler low-voltage fuse
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements