E201
Lennox Indoor Unit Communication Loss

Thermostat shows E201 and reports loss of communication with the indoor unit only; cooling or heating may not respond.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or reversed ABCD wiring between thermostat and Lennox indoor unit, Failed indoor unit control board communication circuit, Shorted low-voltage cable between thermostat and furnace/air handler, Incorrectly wired add-on accessory (humidifier, dehumidifier) on indoor unit terminals

How to Fix / Troubleshooting

Safety warning: Always shut off power to the furnace/air handler at the breaker and service switch before removing panels.

  • 1. Verify indoor unit power:
    • Confirm the furnace/air handler breaker is ON.
    • Check that the blower door is properly closed and engaging the door switch.
  • 2. Inspect ABCD or R/C/Y/W wiring:
    • Remove the thermostat from the wall and inspect the communication or conventional terminals.
    • At the indoor unit control board, verify the same wires land on the correct terminals.
    • Look for pinched, cut, or burnt low-voltage wires near the cabinet entry.
  • 3. Disconnect accessories temporarily:
    • If a Lennox humidifier, dehumidifier, or air cleaner is wired to the board, disconnect its low-voltage leads.
    • Power cycle the system and see if E201 clears, indicating an accessory wiring fault.
  • 4. Check board status LEDs:
    • Observe the Lennox control board LED pattern; if it indicates a board fault, consult the unit's service label.
    • If the board is not powering up or shows communication failure, it may need replacement.
  • 5. Call a professional if unresolved:
    • Communication faults often require board replacement and firmware checks; schedule service with a Lennox-authorized technician.