E13
Lux Compressor Stage 1 Output Fault

Thermostat displays E13 and will not energize compressor (Y output)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted Y wire to C, Failed Y relay on thermostat, Shorted contactor coil in outdoor unit

How to Fix / Troubleshooting

Safety: Turn off both indoor and outdoor unit breakers before working on wiring.

  • Inspect Y wiring at thermostat: Remove the Lux thermostat and check the Y wire for damage or shorts to other conductors.
  • Isolate Y circuit: Disconnect the Y wire at the thermostat, restore power, and see if E13 clears. If it does, the issue is downstream.
  • Check outdoor unit: At the condenser, inspect the contactor coil wiring connected to Y and C. Look for burned insulation or insect damage.
  • Measure coil resistance: With power off, measure resistance across the contactor coil. A very low resistance may indicate a shorted coil that can overload the thermostat output.
  • Repair/replace contactor: Replace the contactor if the coil is shorted or physically damaged.
  • Replace thermostat: If E13 persists with Y disconnected, the internal Y relay is likely failed and the thermostat should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lux Smart Thermostat Y Output Circuit
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements