Possible Causes

Loose W/W1 wire at Lux wall plate, Misconfigured system type (set to cool-only), Open heating relay on furnace board

How to Fix / Troubleshooting

Safety: Turn off HVAC power at the breaker before touching wiring.

  • Verify mode: Ensure the Lux thermostat is set to HEAT mode and not OFF or COOL.
  • Check setpoint: Raise the set temperature at least 3–5°F above the displayed room temperature.
  • Inspect W/W1 wiring: Remove the thermostat and confirm the W or W1 wire is securely clamped in the correct terminal and not broken.
  • System configuration: In the installer menu, confirm the system type is set to conventional heat or heat pump as appropriate, and that heating stages are enabled.
  • Bypass test (advanced): With power on and thermostat removed, briefly jumper R to W at the wall plate. If the furnace starts, the thermostat is not sending a heat call and may be defective or misconfigured. Remove the jumper immediately after test.
  • Call technician: If jumpering R to W does not start heat, the issue is in the furnace or control board and requires HVAC service.