Lux Voltage Sag or Electrical Noise on 24VAC Supply

Thermostat reboots or resets when heating or cooling starts

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak 24VAC transformer, Shared power with high-load accessories (humidifier, UV light), Loose R or C connection at Lux wall plate

How to Fix / Troubleshooting

Safety: Turn off HVAC power before inspecting wiring.

  • Inspect R and C connections: Ensure the R and C wires are tightly secured at both the Lux wall plate and the furnace control board.
  • Check accessory wiring: If a humidifier, dehumidifier, or UV light is powered from the same transformer, verify proper wiring and that loads are within transformer rating.
  • Measure voltage under load: With a multimeter, measure 24VAC between R and C while the system is idle and while it is running. A large drop indicates transformer or wiring issues.
  • Upgrade transformer: Have an HVAC technician replace the transformer with a higher VA rating if it is undersized.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

HVAC 24VAC Control Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements