Meross Stuck Heating Relay / Output Permanently On

Heating runs continuously and does not turn off even when the set temperature is reached or the thermostat is turned off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Welded relay contacts due to overcurrent, Miswired permanent live bypassing thermostat, Shorted triac in solid-state output

How to Fix / Troubleshooting

Safety first: Immediately switch off the heating circuit breaker to prevent overheating or damage to the system.

Steps:

  • Confirm thermostat command: Set the thermostat to OFF or a very low setpoint. If the boiler or heater continues to run, the issue is in wiring or hardware.
  • Check wiring: With power off, verify that the live feed to the boiler or heater passes only through the thermostat's designated output terminals. Remove any unauthorized bypass connections.
  • Test relay contacts: Disconnect the output wires from the thermostat and restore power. If the heater stops, the thermostat was driving it. If the heater still runs, the fault is in external wiring or controls.
  • Inspect thermostat output: With the thermostat removed and power off, measure continuity across the relay contacts (e.g., COM and NO). If continuity is present even when the thermostat is off, the relay is welded closed.

Resolution: Replace the thermostat if the relay or triac is stuck. Do not attempt to pry open or file relay contacts.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heating Output Relay / Triac
Check Price on Amazon