E294
Nest R Wire Configuration / Detection Fault

Nest thermostat displays E294 and reports that it cannot detect the R wire or that the R wire is misconfigured

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

R wire inserted into wrong Nest terminal, R wire not fully seated in R terminal, R wire broken or open in thermostat cable, Furnace control board R terminal not providing 24V

How to Fix / Troubleshooting

Safety: Turn off power to the HVAC system before adjusting wiring.

  • Verify R placement: Remove the Nest display and confirm the 24V hot wire is in the R terminal (Rc/Rh combined on many Nest models), not in another terminal.
  • Re‑strip and reinsert: Cut back the R conductor to clean copper, strip 3–4 mm, and reinsert firmly into the R terminal until the clamp clicks.
  • Check at furnace: Confirm the same conductor is attached to the R terminal on the furnace control board and that 24 VAC is present between R and C.
  • Continuity test: With power off, test continuity of the R conductor between furnace and thermostat. Replace cable or use a spare conductor if open.
  • Board output: If there is no 24 VAC at the furnace R terminal, the transformer or control board is likely faulty and needs professional replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

R Conductor in Thermostat Cable or Furnace Control Board