Netatmo Stuck Relay Contact Closed

Boiler runs continuously even when the thermostat setpoint is reached and the app shows no call for heat.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Welded dry‑contact relay inside Netatmo Relay, Incorrect wiring bypassing thermostat, Boiler internal fault ignoring thermostat input

How to Fix / Troubleshooting

Danger: Boiler and Relay wiring may carry mains voltage. Switch off power at the breaker and boiler switch before touching any wires.

  • Check app status: Confirm in the Netatmo app that the thermostat is not calling for heat (no flame icon).
  • Isolate thermostat circuit: With power OFF, disconnect one thermostat control wire at the boiler. Restore power briefly: if the boiler still runs, the issue is inside the boiler, not the Netatmo Relay.
  • Test Relay contact: If the boiler stops when the thermostat wires are removed but runs when they are connected, the Relay contact may be stuck closed. Replace the Netatmo Relay.
  • Inspect for bypass wiring: Ensure no installer has bridged the thermostat terminals permanently inside the boiler.

Continuous boiler operation can waste energy and damage the system; if you cannot safely diagnose the wiring, contact a heating technician immediately.