E5
Payne Low Voltage / Power Supply Fault

Thermostat displays E5 and backlight may dim or flicker; system may intermittently reboot or shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient 24VAC from Payne furnace/air handler transformer, Loose R and C connections at thermostat or control board, Overloaded 24V transformer due to added accessories, Failing internal power regulator on thermostat PCB

How to Fix / Troubleshooting

Safety first: Turn off power to the furnace/air handler before accessing the control compartment.

  • Check R and C wiring: Remove the thermostat and verify that the R (or Rc/Rh) and C terminals are firmly connected and not corroded. At the indoor control board, confirm the R and C wires are secure on the Payne control board terminals.
  • Measure transformer voltage (advanced): With power on and using a multimeter set to AC volts, measure between R and C at the control board. You should see around 24VAC (typically 24–28VAC). If voltage is low or drops significantly when the system starts, the transformer may be undersized or failing.
  • Reduce accessory load: Temporarily disconnect non‑essential 24V accessories (humidifier, UV lights, zoning dampers) to see if E5 clears. If it does, the transformer may be overloaded and should be upgraded per Payne specifications.
  • Inspect for loose neutrals or breakers: At the electrical panel, ensure the breaker feeding the furnace/air handler is fully seated and that neutral connections are tight (licensed electrician recommended).
  • Thermostat reset: Perform a factory reset from the thermostat menu. If E5 persists with proper 24VAC, the internal power supply on the thermostat may be defective and the thermostat should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Payne Furnace/Air Handler 24V Transformer